Skip to main content
Back to Resources

Accuracy Standards

ISO 230-1 and 2 Guide

Use ISO 230-1 and ISO 230-2 as a procurement filter for geometric accuracy, positioning accuracy, and repeatability claims.

How to Use These Standards

  • Use ISO 230-1 when you need geometric checks such as straightness, squareness, and axis relationship.
  • Use ISO 230-2 when you need axis positioning accuracy and repeatability data.
  • Require the test report, not only a brochure number, when tolerances affect the buying decision.

Method Split Before Acceptance

Acceptance questionUse ISO 230-1 when...Use ISO 230-2 when...
What is out of tolerance?Straightness, squareness, parallelism, spindle alignment, or axis relationship.Commanded-vs-measured axis position, repeatability, or reversal behavior.
What evidence should be requested?Geometric inspection record with setup, instrument, reference surface, and measured deviations.Laser/interferometer report with target positions, approach directions, environment, and uncertainty statement.
What limit decides pass/fail?The signed acceptance sheet, builder declaration, or customer quality plan.The same contract source, not a generic ISO number copied from another machine.

Equipment Selection Handoff

Use the equipment selection calculator to connect ISO accuracy requirements with work envelope, process fit, budget, and support constraints.

Use the ISO 230 reference table when you need a compact comparison of accuracy terms and test-report fields.